Schneider Electric OFS Stack Buffer Overflow

CVE-2014-0774

Assigned byThe organization (CNA) that assigned this CVE ID and published the record, usually the vendor.
ICS-CERT (opens in new tab)
Published
Last modified
NVD status
Modified
CVSS 2.06.9Medium

Description

Stack-based buffer overflow in the C++ sample client in Schneider Electric OPC Factory Server (OFS) TLXCDSUOFS33 - 3.35, TLXCDSTOFS33 - 3.35, TLXCDLUOFS33 - 3.35, TLXCDLTOFS33 - 3.35, and TLXCDLFOFS33 - 3.35 allows local users to gain privileges via vectors involving a malformed configuration file.

Exploitation

Whether attackers are exploiting this vulnerability, and how likely they are to try in the next 30 days.

FIRST Exploit Prediction Scoring System (EPSS)About EPSS (opens in new tab)

FIRST's estimate of the chance attackers try to exploit this vulnerability in the next 30 days.

Probability of exploitationIt predicts attempts, not success, and is updated daily.
0.467%
Compared with other CVEs
At or above 41.272% of scored CVEs
Scored

Affected products

The products and versions with the vulnerability.

Listed by CNA

The products and versions affected, according to the organization that published this CVE.

VendorProductAffected versions
Schneider ElectricTLXCDSUOFS33
  • V3.35
Schneider ElectricTLXCDSTOFS33
  • V3.35
Schneider ElectricTLXCDLUOFS33
  • V3.35
Schneider ElectricTLXCDLTOFS33
  • V3.35
Schneider ElectricTLXCDLFOFS33
  • V3.35

Listed by NVD

The CPE names vulnerability scanners match, including products that bundle the affected software.

VendorProductTypeVulnerable versions
schneider-electricofs test client tlxcdlfofs33Application
  • 3.35
schneider-electricofs test client tlxcdltofs33Application
  • 3.35
schneider-electricofs test client tlxcdluofs33Application
  • 3.35
schneider-electricofs test client tlxcdstofs33Application
  • 3.35
schneider-electricofs test client tlxcdsuofs33Application
  • 3.35
schneider-electricopc factory serverApplication
  • 3.35

How to fix the vulnerability, or reduce the risk until you can.

Solutions

From ICS-CERT, which published this CVE.

Schneider Electric has a product upgrade as well as a workaround
solution
that mitigates this
vulnerability. 

Schneider Electric Security Notification SEVD
2014-031-01,”Vulnerability Disclosure – OPC Factory Server V3.35,”
http://www.downloads.schneider-electric.com/?p_Conf=&p_localesFilter=&p_docTypeFilter=155589... http://www.downloads.schneider-electric.com/    

The security announcements affecting the OPC Factory Server are available here:

http://www2.schneider-electric.com/sites/corporate/en/support/cybersecurity/cybersecurity.page

Schneider
Electric recommends customers to upgrade to OFS v3.4 or later (Version
v3.5 is currently available). Customers that cannot upgrade are directed
to remove the demonstration client from affected computers, provided it
is not required for operations.

Severity

How serious the vulnerability is if exploited, scored from 0 to 10 with the CVSS standard (opens in new tab).

  • 6.9 MediumCVSS 2.0 · PrimaryPrimary scores are NVD's own. Secondary scores come from the organization that published the CVE, or from CISA. · Scored by NVD (opens in new tab)
    Attack vectorWhere the attacker has to be. Network is the widest: anywhere on the Internet.
    Local
    Attack complexityWhether the attack depends on conditions the attacker doesn't control.
    Medium
    AuthenticationHow many times the attacker has to sign in.
    None
    ConfidentialityHow much data the attacker can read.
    Complete
    IntegrityHow much data the attacker can change.
    Complete
    AvailabilityHow much the attacker can disrupt the system or service.
    Complete

    AV:L/AC:M/Au:N/C:C/I:C/A:CView in NVD's calculator (opens in new tab)

  • 6.8 MediumCVSS 2.0 · SecondaryPrimary scores are NVD's own. Secondary scores come from the organization that published the CVE, or from CISA. · Scored by ICS-CERT (opens in new tab)
    Attack vectorWhere the attacker has to be. Network is the widest: anywhere on the Internet.
    Local
    Attack complexityWhether the attack depends on conditions the attacker doesn't control.
    Low
    AuthenticationHow many times the attacker has to sign in.
    Single
    ConfidentialityHow much data the attacker can read.
    Complete
    IntegrityHow much data the attacker can change.
    Complete
    AvailabilityHow much the attacker can disrupt the system or service.
    Complete

    AV:L/AC:L/Au:S/C:C/I:C/A:CView in NVD's calculator (opens in new tab)

Weaknesses and attack patterns

The type of bug behind the vulnerability, and how attackers exploit that type.

  • Stack-based Buffer Overflow · CWE-121 (opens in new tab)

    The product writes past the end of a buffer that was allocated on the stack.

    Likelihood of exploitHow likely MITRE rates attacks on this type of weakness, in general rather than for this vulnerability.
    High
    Abstraction
    Variant
    Mapping guidance
    Allowed
  • Improper Restriction of Operations within the Bounds of a Memory Buffer · CWE-119 (opens in new tab)

    The product performs operations on a memory buffer, but it reads from or writes to a memory location outside the buffer's intended boundary.

    Likelihood of exploitHow likely MITRE rates attacks on this type of weakness, in general rather than for this vulnerability.
    High
    Abstraction
    Class
    Mapping guidance
    Discouraged
    Part of

References

Advisories, patches, exploits and more about this vulnerability.

This product uses the NVD API but is not endorsed or certified by the NVD (opens in new tab). CVE records from the CVE List (opens in new tab), weakness types from MITRE's CWE (opens in new tab)™ and attack patterns from its CAPEC (opens in new tab)™ are © The MITRE Corporation, used under the CVE (opens in new tab), CWE (opens in new tab) and CAPEC (opens in new tab) terms of use. Known exploited vulnerabilities and SSVC assessments are from CISA. Exploit predictions are from FIRST's EPSS (opens in new tab). About this data